VERSION 2.67
7/06/06 added PW535B engine. VERSION 2.66 2/17/05 fixed sn in printouts and review. Removed eng hours/cycles. VERSION 2.65 11/8/04 added washer weights to all engines. VERSION 2.64 10/4/04 fixed sn in review. VERSION 2.63 4/12/04 Added washer weights for PW535A. Added PW545B engine. VERSION 2.62 1/09/04 Added engine hours / cycles fields. Changed engine s/n field to match pw vib survey VERSION 2.61 6/03/02 Added -7 Weight to PW535 engine
VERSION 2.60 7/24/01 Added N1Probe
w/517 to tach source options. VERSION 2.59 6/19/01
Added support for TEC-517 speed reporting Updated
for Y2K Compliance VERSION 2.56 Dropped PW304. Changed PW308 Washer Weights to remove weight of A washer from all
combinations. VERSION 2.55 Added 308 Turbine to Test Cell Version VERSION 2.54 Unknown VERSION 2.53 3/04/99 Fixed bug where two weight split used unavailable holes. Added statistical calcs on
average. Added error bars on acquisition screen. Compute ICF using all possible
combinations with mass weighting. Predict solution from current vibration rather than
starting vibrations. Changed 328Jet sensor to 2.779 Volts / Ips. Changed PW308 washer
weight table to permit double washers. Added logic to select washer or saddle weights on
PW308. Added weight table and hole layouts for PW308 weight table. Updated Influence
Coefficients for PW306 and PW308. VERSION 2.52 2/18/99 Added default ICF for 300 series turbines. updated turbine weight table for 306A/B
turbine. Minor modifications to 305A/B turbine weight table. Defined good turbine
vibration as 0.15. VERSION 2.51 1/22/99 Fixed bug in optimizer. Added ICF for PW306. Fixed Bug in weight table for 306A. Added
logic to vary weight based on hole position to compensate for weight of rivets. VERSION 2.5 12/31/99 Added 306B and 308A models
Finalized per X.E.S. 3391 Rev. C (Feb. 17, 1996).
(1) First balance speed = entered speed - 500.0 for Fans.
(1) Added: First balance speed = entered speed - 400.0 for Turbines.
(1) Changed: default detail_weight_entry to YES. VERSION 2.05 3/12/1996 (1) Extended restart job age to 80 hours. (2) Modified sensitivity for PW305. |
||||
|