1. New Main Rotor Process: (If the user uses the default process flow, he just needs to press ENTER).

1> Add "Select Condition" Screen:

a> If a condition has been measured but selected again, give warning.

b> If a GROUP of conditions have been measured and their measurements exceed limits but not corrected yet, and a condition of another GROUP is being selected, give warning.

c> Where necessary, a BACKUP/NOTEPAD can be selected to go back the "Resume/Retake Screen" where "Make Corrections", ..., can be selected.

d> Any time, the "DIAGNOSTIC" key can be pressed to go back to the "Balance Menu" where the user can do "Review" job. After that, the user can use "Resume" to continue the job.

2> In the "Resume/Retake Screen", add "Make Corrections", "Next Condition", and "End Job". A good feature here: If there is more than one condition (FLT80, FLT100, FLT130), after one of them has been measured, all conditions are displayed here. The user does NOT need to go back to the "Select Condition" Screen, if continue to measure the other conditions, just move the cursor to an item and press ENTER to "Retake".

3> Add "Select Corrections" screen:

a> The user can change "Yes" to "NO".

b> If "NO" is displayed, the item is not accessible.

c> On entry to the screen, the default corrections are displayed. But if the associated measurements are not done yet, the corresponding item is set to "NO" and not accessible.

d> While the cursor is on an item, if "EXP" key is pressed, the solution of that item will be displayed to assist the user to make decision.

Press "EXP" again will bring the user back to the screen.

e> While the cursor is on "CURSOR HERE WHEN DONE", if "EXP" key is pressed, ALL the solutions will be displayed to assist the user to make decision. Then go back to the screen.

f> At this screen, the "DIAGNOSTIC" key can be pressed to go back to the "Balance Menu", then the user can use "Resume" to continue the job. At this time, will bring the user to the "Resume/Retake" screen where the user can do "Retake data", "Make Correction", ...


VERSION 3.09, 03/01/98

1. Allow to select letters for ShipId or Eng serial number.

VERSION 3.10, 04/26/98

1. Allow user to do any measurements of any conditions before doing any adjustments.

2. If more than one group of measurements (e.g. Ground & Hover) were done for one default adjustment (e.g. Weight), then the maximum solution group's measurements are selected for adjustment.

3. Hover uses vibe for PCL (prev: used track levels).

4. Update Tail Rotor setup graphics to show rotation directions.


VERSION 3.20, 05/11/98

1. Fully support Year 2000 format.

2. Support PCL and TAB solutions/records with 1/10 precision (one decimal point). This was already in previous versions but the entry screens are fixed for broken fields due to too many digits input.

3. Rotate Tail 801-plain by (-245) degrees, and Tail 801-Arms by (-90) deg.

 
 

 